• OBJECTIVES
    • To determine the proportion of patients requiring secondary surgery for symptomatic implant removal after open reduction, internal fixation using dual mini-fragment plating technique for clavicular shaft fractures.
  • DESIGN
    • Retrospective observational study.
  • SETTING
    • Single university Level 1 trauma center.
  • PATIENTS
    • Eighty-one patients treated with open reduction, internal fixation using dual mini-fragment plating technique for clavicular shaft fractures (OTA/AO 15-B1, B2, and B3) with minimum 12-month follow-up (median 477 days; range 371-1549 days).
  • INTERVENTION
    • Open reduction, internal fixation using dual mini-fragment plating technique for clavicular shaft fractures.
  • MAIN OUTCOME MEASUREMENTS
    • Incidence of secondary surgery, QuickDASH (Disabilities of the Arm, Shoulder, and Hand) scores.
  • RESULTS
    • Six of 81 patients (7.4%) underwent secondary surgery for implant removal for any reason. Of these, 3 (3.7%) underwent symptomatic implant (soft-tissue irritation) removal, 2 (2.5%) required implant removal in the setting of infection, and 1 patient (1.2%) required revision open reduction internal fixation for early implant failure. The mean QuickDASH score in this series was 8.44 (±6.94, range 0-77.27). The associated implant cost of the typical construct utilized in this series was $1511.38. The mean surgical time was 97 minutes (range 71-143 minutes).
  • CONCLUSIONS
    • The utilization of a dual mini-fragment plating technique in the treatment of clavicular shaft fractures results in a low rates of secondary surgery for symptomatic implant removal (3.7%) and similar QuickDASH scores when compared with historical controls treated with 3.5-mm plates placed on the superior clavicle. Potential disadvantages in using this technique include a higher surgical implant cost and length of surgery.
  • LEVEL OF EVIDENCE
    • Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.