• ABSTRACT
    • Highly cross-linked polyethylene (HXLPE) has become the preferred bearing surface in total hip arthroplasty. However, its acceptance in total knee arthroplasty (TKA) has not been as robust because of concerns pertaining to wear and its impact on implant failure. Therefore, this multicenter study was purposed to evaluate the 10-year (1) radiographic outcomes; (2) complications; and (3) implant survivorship in patients with TKA receiving a sequentially irradiated and annealed HXLPE. A retrospective, multi-center study was performed on 139 patients (171 TKAs) who underwent primary TKA with HXLPE and possessed a minimum of 10-year follow-up. Radiographs were analyzed for radiolucencies along the implant-fixation interface using the Modern Knee Society Radiographic Evaluation System. Kaplan-Meier analysis determined implant survivorship when the end points were revision for polyethylene wear and polyethylene revision for any reason. Sixteen TKAs (9.9%) demonstrated periprosthetic linear radio-lucencies. Seventeen TKAs (9.9%) required additional surgeries, 9 (5.3%) of which were revisions, with 1 (0.6%) TKA requiring revision because of polyethylene wear. Other causes of revision included instability (1.8%), infection (1.6%), and arthrofibrosis (1.6%). The mean time to revision was 5.9 years (range, 0.1-11.1 years). Survivorship pertaining to polyethylene revision for wear was 99.4%, whereas all-cause polyethylene revision was 94.7%. This study in patients undergoing primary TKA using a second-generation HXLPE demonstrated excellent results with respect to polyethylene wear characteristics and strength with a 99.4% survivorship at 10 years. [Orthopedics. 2023;46(2):e111-e117.].