• BACKGROUND
    • Glenoid baseplate malpositioning during reverse total shoulder arthroplasty can contribute to perimeter impingement, dislocation, and loosening. Despite advances in preoperative planning, conventional instrumentation may lead to considerable inaccuracy in implant positioning unless patient-specific guides are used. Optical navigation has the potential to improve accuracy and precision when implanting a reverse shoulder arthroplasty baseplate. This systematic review aimed to analyze the most recent evidence on the accuracy and precision of glenoid baseplate positioning using intraoperative navigation and its potential impact on component selection and surgical time.
  • METHODS
    • We conducted a systematic review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. The PubMed, Scopus, and EMBASE databases were queried in July 2022 to identify all studies that compared navigation vs. conventional instrumentation for reverse shoulder arthroplasty. Data of deviation from the planned baseplate version and inclination, the use of standard or augmented glenoid components, and surgical time were extracted. Quantitative analysis from the included publications was performed using the inverse-variance approach and Mantel-Haenszel method.
  • RESULTS
    • Of the 2,048 records identified in the initial query, only 10 articles met the inclusion and exclusion criteria, comprising 667 shoulders that underwent reverse total shoulder arthroplasty. The pooled mean difference (MD) of the deviation from the planned baseplate position for the clinical studies was -0.44 (95% confidence interval [CI], -3.26; p = 0.76; I2 = 36%) for version and -8.75 (95% CI, -16.83 to -0.68; p = 0.02; I2 = 83%) for inclination, both in favor of navigation. The odds ratio of selecting an augmented glenoid component after preoperative planning and navigation-assisted surgery was 8.09 (95% CI, 3.82-17.14; p < 0.00001; I2 = 60%). The average surgical time was 12 minutes longer in the navigation group (MD 12.46, 95% CI, 5.20-19.72; p = 0.0008; I2 = 71%).
  • CONCLUSIONS
    • Preoperative planning integrated with computer-assisted navigation surgery seems to increase the accuracy and precision of glenoid baseplate inclination compared with the preoperatively planned placement during reverse total shoulder arthroplasty. The surgical time and proportion of augmented glenoid components significantly increase when using navigation. However, the clinical impact of these findings on improving prosthesis longevity, complications, and patient functional outcomes is still unknown.
  • LEVEL OF EVIDENCE
    • Level III, systematic review and meta-analysis. See Instructions for Authors for a complete description of levels of evidence.