• ABSTRACT
    • The purpose of this study was to measure the radiographic parameters of proximal pole scaphoid fractures, and calculate the ideal starting points and trajectories for antegrade screw insertion. Computed tomography scans of 19 consecutive patients with proximal pole fractures were studied using open source digital imaging and communications in medicine (DICOM) imaging measurement software. For scaphoid sagittal measurements, fracture inclination was measured with respect to the scaphoid axis. The ideal starting point for a screw in the proximal pole fragment was then identified on the scaphoid sagittal image that demonstrated the largest dimensions of the proximal pole, and hence the greatest screw thread purchase. Measurements were then taken for a standard screw trajectory in the axis of the scaphoid, and a trajectory that was perpendicular to the fracture line. The fracture inclination in the scaphoid sagittal plane was 25 (SD10) °, lying from proximal palmar to dorsal distal. The fracture inclination in the coronal plane was 9 (SD16) °, angling distal radial to proximal ulnar with reference to the coronal axis of the scaphoid. Using an ideal starting point that maximized the thread purchase in the proximal pole, we measured a maximum screw length of 20 (SD 2) mm when using a screw trajectory that was perpendicular to the fracture line. This was quite different from the same measurements taken in a trajectory in the axis of the scaphoid. We also identified a mean distance of approximately 10 mm from the dorsal fracture line to the ideal starting point. A precise understanding of this anatomy is critical when treating proximal pole scaphoid fractures surgically.