• INTRODUCTION
    • The aim of the study is to compare three different fixation techniques for transverse olecranon repair in cadaveric osteoporotic bone: (1) current recommended AO tension band technique with K-wire fixation; (2) Suture anchor fixation and (3) Polyester suture fixation.
  • METHODS
    • Evaluated with bone densitometry, 7 osteoporotic human elbow specimens were included in the study. A transverse olecranon fracture was reduced anatomically and were fixated first using a K-wire tension band technique, second using two suture anchors, and third using polyester suture. Static simulations of the kinetics associated with active range of motion (AROM) and push up from a chair exercises were performed with cyclic loading using Instron hydraulic testing apparatus. Fracture displacement was measured using videographic analysis. Failure was defined as 2 mm fracture displacement.
  • RESULTS
    • The biomechanical analysis found no statistical difference in displacements between the three fixation methods when testing AROM. In simulated push-up exercises, polyester suture fixation failed after 17 cycles and had significantly higher displacement compared to the other two methods. No difference between the K-Wire fixation versus Suture anchor fixation was observed, p = 0.162.
  • CONCLUSION
    • Suture anchor fixation might be a viable surgical treatment option for osteoporotic transverse elbow fractures in geriatric patients.