• BACKGROUND
    • Management of displaced acromioclavicular joint (ACJ) injuries remains contentious. It is unclear if delayed vs. acute reconstruction has an increased risk of fixation failure and complications. The primary aim of this study was to compare complications of early vs. delayed reconstruction. The secondary aim was to determine modes of failure of ACJ reconstruction requiring revision surgery.
  • METHODS
    • A retrospective study was performed on all patients who underwent operative reconstruction of ACJ injuries over a 10-year period (Rockwood III-V) using suspensory devices with or without hamstring allograft. Reconstruction was classed as early (<12 weeks from injury) or delayed (≥12 weeks). Patient demographics, fixation method, and postoperative complications were noted, with 1-year follow-up a minimum requirement for inclusion. Patient-reported outcomes with the Disabilities of the Arm, Shoulder, and Hand score and EuroQol-5 Dimension were undertaken. Fixation failure was defined as loss of reduction requiring revision surgery.
  • RESULTS
    • A total of 104 patients were analyzed (n = 59 early and n = 45 delayed). The mean age was 42.0 (standard deviation: 11.2; 17-70 years); 84.6% were male and 15.4% were smokers. No difference was observed between fixation failure (P = .39) or deep infection (P = .13) with regard to acute vs. delayed reconstruction. No patient demographic or timing of surgery was predictive of fixation failure on regression modeling. Overall, 11 patients underwent revision surgery for loss of reduction and implant failure (n = 5 suture fatigue, n = 2 endobutton escape, n = 2 coracoid stress fracture, and n = 2 deep infection). The EuroQol-5 Dimension (P = .084) and Disabilities of the Arm, Shoulder, and Hand score (P = .062) were comparable for early and delayed groups respectively and below the minimal clinically important difference.
  • CONCLUSION
    • This study found that delayed surgical management of ACJ injuries using a modern device has comparable functional outcomes and is not associated with a higher incidence of fixation failure or major complications.