• BACKGROUND
    • Pseudoarthrosis is a complication of spinal fixation. Risk factors include infection, larger constructs, significant medical comorbidities, and diabetes. The authors present a case report of dilated pedicle screw pseudoarthrosis salvaged with moldable, settable calcium phosphate-based putty.
  • OBSERVATIONS
    • The patient presented with back pain and radiculopathy in the setting of poorly controlled diabetes. He was taken to the operating room for laminectomy and fusion complicated by postoperative infection requiring incision and drainage. He returned to the clinic 6 months later with pseudoarthrosis of the L4 screws and adjacent segment degeneration. He was taken for revision with extension of fusion. The L4 tracts were significantly dilated. A moldable, bioabsorbable polymer-based putty containing calcium phosphate was used to augment the dilated tract after decortication back to bleeding bone, allowing good purchase of screws. The patient did well postoperatively.
  • LESSONS
    • There are several salvage options for clinically significant pseudoarthrosis after spinal fixation, including anterior or lateral constructs, extension, and revision of fusion. The authors were able to obtain good screw purchase with dilated screw tracts after addition of moldable, bioabsorbable polymer-based putty containing calcium phosphate. It appears that this may represent an effective salvage strategy for dilated pseudoarthropathy in select settings to support extension of fusion.