• ABSTRACT
    • The surgical treatment of proximal humerus fractures, though common, is associated with surprisingly high complication rates upward of 34%. Obtaining a reduction and placing a stable fixation can be challenging because many fractures treated surgically are comminuted and occur in osteoporotic bone. Nevertheless, innovations in technique and implant design are mitigating some failures. These innovations include the use of fibular strut allograft and other fixation adjuncts, the correct placement of calcar screws and other locking fixation, and having a systematic approach to reduction and intraoperative imaging to ensure the restoration of anatomy. This review and accompanying video highlight various technical strategies to maximize the success of surgical treatment for these challenging injuries.