• CASE
    • An 85-year-old woman with a history of bladder mesh sling placement sustained a pelvic fracture and extraperitoneal bladder rupture after a ground-level fall. The patient underwent cystorrhaphy and percutaneous anterior column screw placement. Free air was identified on abdominal computed tomography scan on postoperative day 5. Exploratory laparotomy revealed a sigmoid colon perforation and extensive bowel adhesions to the anterior pelvis.
  • CONCLUSION
    • This is the first report describing bowel injury and associated bladder rupture in a pelvic fragility fracture related to a prior bladder mesh sling. This case highlights the importance of obtaining a thorough surgical history when treating pelvic injuries.