Please confirm topic selection

Are you sure you want to trigger topic in your Anconeus AI algorithm?

Please confirm action

You are done for today with this topic.

Would you like to start learning session with this topic items scheduled for future?

Femoral Shaft Fractures
Updated: Dec 5 2024

[Blocked from Release] T2 Alpha™ Femur Antegrade GT/PF Nailing System

Images
https://upload.orthobullets.com/topic/423219/images/a52de077-0b7b-4d79-97d9-f909ab89e869_t2_alpha_antegrade_gt_1..jpg
https://upload.orthobullets.com/topic/423219/images/a11ee523-2f17-4ae5-aea2-8e1e9dd16ec9_t2_alpha_antegrade_pf_1a.jpg
https://upload.orthobullets.com/topic/423219/images/401b1048-d571-40d8-9173-12ffd9b085df_t2_alpha_antegrade_pf_1b.jpg
  • T2 Alpha Design
    • GT / PF Nailing System
      • The T2 Alpha Femur Antegrade GT / PF Nailing System is intended for temporary stabilization of bone segments or fragments until bone consolidation has been achieved.
      • T2 Alpha Femur Antegrade GT / PF Nailing System includes two options for antegrade femoral nailing: The Femoral Nail GT for greater trochanteric entry and the Femoral Nail PF for piriformis fossa entry.
    • Intraoperative Adaptability
      • 2 Alpha provides our customers with a platform capable of quickly adapting to varying intraoperative needs. 
      • With nails designed for preferred entry, length dependent radius of curvature, and added locking configurations, T2 Alpha delivers a comprehensive implant portfolio to meet the diverse anatomical needs of patients. 
    • Advanced Locking Screws
      • Provide increased axial fracture stability in any 5mm round locking hole when the surgeon chooses.
    • IMN Locking Screws
      • IMN locking screw design provides increased fatigue strength compared to competition.
    • Streamlined Instrumentation Platform
      • One core basic tray that is used across Gamma4 and all T2 Alpha nail indications, designed to improve platform consistency and ease of use.
      • Designed to provide reproducible locking, and reduce the total number of x-ray shots compared to freehand locking.
  • Technical specifications
    • Nail diameter Ø9mm – Ø15mm
    • Nail length 240mm – 480mm in 20mm increments
    • Locking Screw Ø5mm, 25mm – 120mm length 25mm - 60mm in 2.5mm increments 60mm - 120mm in 5mm increments
    • Advanced Locking Screws Ø5mm, 30mm – 100mm length 30mm - 60mm in 2.5mm increments 60mm - 100mm in 5mm increments
    • T2 Lag Screws Recon Ø6.5mm, 65mm – 130mm length
  • Screws
    • Femur Antegrade GT/PF Nailing System
      • Femur Antegrade GT/PF Nailing System
      • Locking Screws
      • Ø5mm, 25mm – 120mm length
      • 25mm - 60mm in 2.5mm increments
      • 60mm - 120mm in 5mm increments
      • Advanced Locking Screws
      • Ø5mm, 30mm – 100mm length
      • 30mm - 60mm in 2.5mm increments
      • 60mm - 100mm in 5mm increments
      • T2 Lag Screws Recon
      • Ø6.5mm, 65mm – 130mm length
Card
1 of 0
Private Note