Femoral Shaft Fractures
Updated: Dec 5 2024

[Blocked from Release] T2 Alpha™ Femur Retrograde Nailing System

Images
https://upload.orthobullets.com/topic/423220/images/d1fd50e8-421c-44f3-a38f-f43b35d05862_t2_alpha_retrograde_and_pangea_distal_lateral_femur_plate_1.jpg
https://upload.orthobullets.com/topic/423220/images/9651eca7-a680-461c-aa71-3f92a1150fa5_t2_alpha_retrograde_and_pangea_distal_medial_femur_plate__1.jpg
https://upload.orthobullets.com/topic/423220/images/115cd561-e50e-4aa3-b772-252b057c8f33_t2_alpha_retrograde_and_pangea_peripro_distal_lateral_femur_1.jpg
https://upload.orthobullets.com/topic/423220/images/2635f55c-d2a1-4003-8faa-94d6e89f008e_t2_alpha_retrograde_and_t2_alpha_tibia_1.jpg
https://upload.orthobullets.com/topic/423220/images/2bc82b90-b0a1-48d0-8127-56604754a9fe_t2_alpha_retrograde__and_pangea_distal_medial_femur_plate__2.jpg
https://upload.orthobullets.com/topic/423220/images/de5dddba-d527-4022-b1e1-6f4210072de2_t2_alpha_retrograde_1.jpg
https://upload.orthobullets.com/topic/423220/images/c4461860-9124-4476-8feb-d8a03981e0fe_t2_alpha_retrograde_2.jpg
https://upload.orthobullets.com/topic/423220/images/0f3b1614-8aec-42df-85e0-11a88420c6bd_t2_alpha_retrograde_4..jpg
  • T2 Alpha Design
    • Alpha Femur Retrograde Nail
      • The T2 Alpha Femur Retrograde Nailing System is intended for temporary stabilization of bone segments or fragments until bone consolidation has been achieved.
    • Updated Locking Configuration
      • Added proximal and distal locking options, three planes of fixation, and the most distal screw 6mm from the driving end of the nail allows for adequate stability and fixation.
    • Advanced Locking Screws
      • Provide increased axial fracture stability in any 5mm round locking hole when the surgeon chooses.
    • IMN Locking Screws
      • IMN locking screw design provides increased fatigue strength compared to competition.
    • Femur Condyle Screws
      • Adjustable condyle screws allow for a range of 2mm longer or 5mm shorter than the actual condyle screw length for compression of femur condyle fragments.
    • Static Targeting Arm
      • Designed to provide stability and procedural ease during distal screw insertion.
  • Technical specifications
    • Nail diameter Ø9mm–Ø14mm
    • Driving end diameter of the 9–11mm nails is Ø11.5mm; nail sizes 12–14mm have a constant diameter
    • Femoral Nail Retrograde, Short: 170mm and 200mm Femoral Nail Retrograde: 220mm– 480mm in 20mm increments
    • Drills 4.2mm – green 5.5mm – green (counterbore drill)
  • Screws
    • Femur Retrograde Nail 
      • Femur Retrograde Nail 
      • Locking Screws
      • Ø5mm, 25mm–120mm length 
      • 25mm–60mm in 2.5mm increments 
      • 60mm–120mm in 5mm increments
      • Advanced Locking Screws
      • Ø5mm, 30mm–100mm length 
      • 30mm–60mm in 2.5mm increments 
      • 60mm–100mm in 5mm increments
      • Condyle Screws & Condyle Nut
      • Ø5mm, 40mm –120mm length in 5mm increments
Card