Tibial Shaft Fractures
Updated: Dec 16 2024

[Blocked from Release] T2 Alpha™ Tibia Nailing System

Images
https://upload.orthobullets.com/topic/423221/images/dc4d1a27-9027-49de-8e90-d11dff246cbd_t2_alpha_tibia_1a.jpg
https://upload.orthobullets.com/topic/423221/images/6251b9ec-5349-4cee-93c0-7017b1e28b52_t2_alpha_tibia_1b.jpg
https://upload.orthobullets.com/topic/423221/images/600819e6-5804-452a-a19f-4004535b23c5_t2_alpha_tibia_2.jpg
  • T2 Alpha Design
    • Tibia Nailing System
      • The T2 Alpha Tibia Nailing System is intended for temporary stabilization of bone segments or fragments until bone consolidation has been achieved.
    • Advanced Nail Design
      • Increased proximal locking options
      • More distal locking pattern with most distal hole remaining 5mm from the tip
      • Up to 7mm of active internal compression
      • Proximal 10 degree Herzog bend
      • 4 degree distal bend
    • Suprapatellar Instrumentation
      • T2 Alpha Tibia Suprapatellar system offers two size options of drill sleeves available to accommodate nail diameters 8-13mm 
      • Elastic nail insertion sleeve designed to serve as a working channel to protect the joint space
      • WCH-coated fixation k-wires designed for secure fixation in tibial plateau to prevent anteriorization and back out of sleeves during reaming
    • Streamlined Instrument Platform
      • Basic instrument tray that is used across all T2 Alpha nailing indications and Gamma4
      • Ergonomic instrumentation that is designed to improve ease of use  
      • Dedicated distal targeting device designed to reduce inconsistences by providing a reproducible step-by-step procedure
    • Stability
      • Advanced locking screws designed for added axial stability 
      • Can be used in all 5mm circular holes 
      • Fatigue strength is 30% stronger than the traditional locking screw
      • Designed to reduce play between the nail and screw
  • Technical specifications
    • Nail diameters Ø8mm – Ø15mm
    •  Nail length 240mm – 420mm in 15mm increments
    • Compression Screw Tibia
    • End Cap Lower Extremity and End Caps Tibia
  • Screws
    • T2 Alpha Tibia Nail
      • T2 Alpha Tibia Nail
      • Locking Screws
      • Ø5mm, 25mm – 120mm length
      • 25mm - 60mm in 2.5mm increments
      • 60mm - 120mm in 5mm increments
      • Advanced Locking Screws
      • Ø5mm, 30mm – 100mm length
      • 30mm - 60mm in 2.5mm increments
      • 60mm - 100mm in 5mm increments
      • Drills
      • 42mm - green 55mm - green (counterbore drill)
      • 35mm - orange 45mm - orange (counterbore drill)